(<tc>NOUVELLE</tc>) Cisco Catalyst 2960 Plus 48 10/100 + 2 T/SFP LAN Base WS-C2960+48TC-L

Spécifications du WS-C2960+48TC-L Configurations Interfaces Ethernet 10/100 48 Interfaces de liaison montante 2 (SFP ou 1000BASE-T) Ensemble...
Vendor: CISCO
SKU: WS-C2960+48TC-L
Availability: In Stock
Product Type: Réseautage
HKD 14,000.00
HKD 14,000.00
Subtotal: HKD 14,000.00
10 customers are viewing this product

Free Shipping

Free standard shipping on orders over $99

Estimated to be delivered on 12/01/2022 - 15/10/2022.

Free Returns

Learn More.

Built And Shipped Within 5 - 7 Bussiness Days

(<tc>NOUVELLE</tc>) Cisco Catalyst 2960 Plus 48 10/100 + 2 T/SFP LAN Base WS-C2960+48TC-L

(<tc>NOUVELLE</tc>) Cisco Catalyst 2960 Plus 48 10/100 + 2 T/SFP LAN Base WS-C2960+48TC-L

HKD 14,000.00

(<tc>NOUVELLE</tc>) Cisco Catalyst 2960 Plus 48 10/100 + 2 T/SFP LAN Base WS-C2960+48TC-L

HKD 14,000.00

Spécifications du WS-C2960+48TC-L

Configurations

Interfaces Ethernet 10/100

48

Interfaces de liaison montante

2 (SFP ou 1000BASE-T)

Ensemble de fonctionnalités du logiciel Cisco IOS

Base LAN

Alimentation PoE disponible

Aucun

Matériel

Mémoire flash

64 Mo

DRACHME

128 Mo

Performances et évolutivité

Transférer la bande passante

16 Gbit/s

Nombre maximal de VLAN actifs

255

ID VLAN disponibles

4K

Unité de transmission maximale (MTU) - Paquet L3

9000 octets

Trame Jumbo - Trame Ethernet

9018 octets

Taux de transfert : paquets L3 de 64 octets, millions de paquets par seconde

10.1

Mécanique

Dimensions (H x L x P)

1,73 x 17,70 x 9,52 pouces (4,4 x 45,0 x 24,2 cm)

Poids

8 livres (3,6 kg)

Poids du colis

17,04 livres (7,73 kg)

Plages environnementales

Température de fonctionnement jusqu'à 5000 pieds (1500 m)

23º à 113ºF

(-5º à 45ºC)

Température de fonctionnement jusqu'à 10 000 pieds (3 000 m)

23º à 104ºF

(-5º à 40ºC)

Exception à court terme au niveau de la mer*

23º à 131ºF

(-5º à 55ºC)

Exception à court terme jusqu'à 5000 pieds (1500 m)*

23º à 122ºF

(-5º à 50ºC)

Exception à court terme jusqu'à 10 000 pieds (3 000 m)*

23º à 113ºF

(-5º à 45ºC)

Exception à court terme jusqu'à 13 000 pieds (4 000 m)*

23º à 104ºF

(-5º à 40ºC)

Température de stockage jusqu'à 15 000 pieds (4 573 m)

23º à 158ºF

(-25º à 70ºC)

Altitude de fonctionnement

Jusqu'à 10 000 pieds

(Jusqu'à 3 000 mètres)

Altitude de stockage

Jusqu'à 13 000 pieds

(Jusqu'à 4 000 mètres)

Humidité relative de fonctionnement

10% à 95% sans condensation

Humidité relative de stockage

10% à 95% sans condensation

Pression acoustique, dBA

Typique, LpAm : 33

Maximum, LpAD : 36

Puissance acoustique, dbA

Typique, LwA : 43

Maximum, LwAD : 46

MTBF en milliers d'heures

623

Connecteurs et interfaces

Interfaces Ethernet

  • Ports 10BASE-T : connecteurs RJ-45, câblage à paires torsadées non blindées (UTP) de catégorie 3, 4 ou 5 à 2 paires
  • Ports 100BASE-TX : connecteurs RJ-45, câblage UTP catégorie 5 à 2 paires
  • Ports 1000BASE-T : connecteurs RJ-45, câblage UTP catégorie 5 à 4 paires
  • Ports SFP 1000BASE-T : connecteurs RJ-45, câblage UTP de catégorie 5 à 4 paires

Voyants LED

  • Statut par port : intégrité du lien, désactivé, activité, vitesse et duplex intégral
  • État du système, état du port, RPS, duplex de liaison et vitesse de liaison

Console

Câbles de console Cisco Catalyst :

  • CAB-CONSOLE-RJ45 Câble de console 6 pi avec RJ-45

Pouvoir

  • L'alimentation interne est une unité à sélection automatique et prend en charge les tensions d'entrée comprises entre 100 et 240 V CA.
  • Utilisez le cordon d’alimentation secteur fourni pour connecter le connecteur d’alimentation secteur à une prise secteur.
  • Le connecteur Cisco RPS offre une connexion pour un Cisco RPS 2300 en option qui utilise une entrée CA et fournit une sortie CC au Switch.
  • Seul le Cisco RPS 2300 (modèle PWR-RPS2300) doit être connecté à la prise du système d'alimentation redondant.

Gestion et soutien aux normes

Gestion

  • PONT-MIB
  • CISCO-CABLE-DIAG-MIB
  • CISCO-CDP-MIB
  • CISCO-CLUSTER-MIB
  • CISCO-CONFIG-COPIE-MIB
  • CISCO-CONFIG-MAN-MIB
  • MIB SNOOPING DHCP CISCO
  • CISCO-ENTITÉ-TYPE-VENDEUR-OID-MIB
  • CISCO-ENVMON-MIB
  • CISCO-ERR-DISABLE-MIB
  • MIB CISCO FLASH
  • CLIENT FTP CISCO MIB
  • Filtre CISCO IGMP MIB
  • CISCO-IMAGE-MIB
  • CISCO-IP-STAT-MIB
  • CISCO-LAG-MIB
  • Notification Cisco MAC MIB
  • CISCO-MEMORY-POOL-MIB
  • CISCO-PAGP-MIB
  • CISCO PING MIB
  • EXTENSIONS CISCO POE MIB
  • Port Cisco QOS MIB
  • CISCO-SÉCURITÉ-PORTUAIRE-MIB
  • CISCO-PORT-STORM-CONTROL-MIB
  • CISCO-PRODUITS-MIB
  • CISCO-PROCESS-MIB
  • CISCO-RTTMON-MIB
  • Cisco SMI MIB
  • EXTENSIONS CISCO STP MIB
  • MIB CISCO SYSLOG
  • CISCO-TC-MIB
  • CICSO-TCP-MIB
  • CISCO-UDLDP-MIB
  • CISCO-VLAN-IFTABLE
  • RELATION-MIB
  • CISCO-VLAN-MEMBERSHIP-MIB
  • CISCO VTP MIB
  • ENTITÉ-MIB
  • MIB de type éther
  • IEEE8021-PAE-MIB
  • IEEE8023-LAG-MIB
  • SI-MIB
  • ADRESSE INET-MIB
  • ANCIEN CHASSIS CISCO MIB
  • ANCIENNE MIB FLASH CISCO
  • ANCIENNES INTERFACES CISCO MIB
  • ANCIENNE MIB IP CISCO
  • ANCIENNE MIB-CISCO-SYS
  • ANCIEN-CISCO-TCP-MIB
  • ANCIEN-CISCO-TS-MIB
  • RFC1213-MIB
  • RMON-MIB
  • RMON2-MIB
  • SNMP-FRAMEWORK-MIB
  • SNMP-MPD-MIB
  • Notification SNMP MIB
  • SNMP-CIBLE-MIB
  • SNMPv2-MIB
  • TCP-MIB
  • MIB UDP
  • ePM-MIB

Normes

  • Protocole Spanning Tree IEEE 802.1D
  • Priorisation CoS IEEE 802.1p
  • Réseau local virtuel IEEE 802.1Q
  • Norme IEEE 802.1s
  • Norme IEEE 802.1w
  • Norme IEEE 802.1X
  • Norme IEEE 802.1ab (LLDP)
  • Norme IEEE 802.3ad
  • Norme IEEE 802.3af
  • IEEE 802.3ah (fibre monomode/multimode 100BASE-X uniquement)
  • Duplex intégral IEEE 802.3x sur les ports 10BASE-T, 100BASE-TX et 1000BASE-T
  • Norme IEEE 802.3 10BASE-T
  • Norme IEEE 802.3u 100BASE-TX
  • Norme IEEE 802.3ab 1000BASE-T
  • Norme IEEE 802.3z 1000BASE-X
  • Normes RMON I et II
  • SNMP v1, v2c et v3

Conformité RFC

  • RFC 768 - UDP
  • RFC 783 - TFTP
  • RFC 791 - IP
  • RFC 792 - ICMP
  • RFC 793 - TCP
  • RFC 826 - ARP
  • RFC 854 - Telnet
  • RFC 951 - Protocole d'amorçage (BOOTP)
  • RFC 959 - FTP
  • RFC 1112 - Multidiffusion IP et IGMP
  • RFC 1157 - SNMP v1
  • RFC 1166 - Adresses IP
  • RFC 1256 - Découverte de routeurs ICMP (Internet Control Message Protocol)
  • RFC 1305 - NTP
  • RFC 1492 - TACACS+
  • RFC 1493 - MIB de pont
  • RFC 1542 - Extensions BOOTP
  • RFC 1643 - MIB d'interface Ethernet
  • RFC 1757 - RMON
  • RFC 1901 - SNMP v2C
  • RFC 1902-1907 - SNMP v2
  • RFC 1981 - Découverte du MTU du chemin pour IPv6
  • FRC 2068 - HTTP
  • RFC 2131 - DHCP
  • RFC 2138 - RAYON
  • RFC 2233 - IF MIB v3
  • RFC 2373 - Adresses agrégées IPv6
  • RFC 2460 - IPv6
  • RFC 2461 - Découverte de voisins IPv6
  • RFC 2462 - Configuration automatique IPv6
  • RFC 2463 - Protocole ICMP IPv6
  • RFC 2474 - Priorité des services différenciés (DiffServ)
  • RFC 2597 - Transfert assuré
  • RFC 2598 - Transfert accéléré
  • RFC 2571 - Gestion SNMP
  • RFC 3046 - Option d'informations sur l'agent relais DHCP
  • RFC 3376 - IGMP v3
  • RFC 3580 - RAYON 802.1X

Tension et puissance nominales

Tension (réglage automatique)

100 à 240 VCA

Courant (Ampères)

0,6 - 0,3

Fréquence

50 à 60 Hz

Puissance nominale (kVA)

0,04

Tensions d'entrée CC (entrée RPS)

3A à 12V

Consommation d'énergie

0% de trafic : 30,4

10% trafic : 30,2

Trafic à 100 % : 30,6

Moyenne pondérée ATIS : 30,2

Sécurité et conformité

Conformité réglementaire

Les produits doivent être conformes au marquage CE conformément aux directives 2004/108/CE et 2006/95/CE

Sécurité

UL 60950-1 Deuxième édition

CAN/CSA-C22.2 No. 60950-1 Deuxième édition

EN 60950-1 Deuxième édition

IEC 60950-1 Deuxième édition

Norme AS/NZS 60950-1

CEM - Émissions

47CFR Partie 15 (CFR 47) Classe A

AS/NZS CISPR22 Classe A

CISPR22 Classe A

EN55022 Classe A

ICES003 Classe A

VCCI Classe A

EN61000-3-2

EN61000-3-3

KN22 Classe A

CNS13438 Classe A

CEM - Immunité

EN55024

CISPR24

EN300386

KN24

Environnement

Réduction des substances dangereuses (RoHS) y compris la directive 2011/65/UE

Nam tempus turpis at metus scelerisque placerat nulla deumantos solicitud felis. Pellentesque diam dolor, elementum etos lobortis des mollis ut risus. Sedcus faucibus an sullamcorper mattis drostique des commodo pharetras loremos.Donec pretium egestas sapien et mollis. Pellentesque diam dolor cosmopolis etos lobortis.

Comodous:
Comodous in tempor ullamcorper miaculis
Mattis laoreet:
Pellentesque vitae neque mollis urna mattis laoreet.
Divamus de ametos:
Divamus sit amet purus justo.
Molestie:
Proin molestie egestas orci ac suscipit risus posuere loremous

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Drostique Nam tempus turpis at metus scelerisque placerat nulla deumantos
Pharetro Lorem Pellentesque diam dolor elementum etos lobortis des mollis
Milancelos Donec pretium egestas sapien et mollis
Pellentesque Sedcus faucibus an sullamcorper mattis drostique des commodo pharetras
Proin Molestie Pellentesque diam dolor elementum etos lobortis des mollis
Cosmopolis Donec pretium egestas sapien et mollis

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Related Products

Recently Viewed Products